Secured Trading Service

Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)

Wenzhou Santuo Electrical Co., Ltd.
  • Audited Supplier
  • 10 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Fast Fault Response: Switches off fault power source within 0.1 seconds when leakage exceeds specified value.
  • Wide Current Range: Available in rated currents from 6A to 63A for diverse electrical needs.
  • Multiple Pole Options: Offers 1P+N and 2P configurations to suit different circuit requirements.
  • High Short-Circuit Capacity: Rated short-circuit capacity up to 6000A ensures robust safety protection.
  • IEC Standard Compliance: Meets IEC/EN 61009-1 standard for electromagnetic residual current circuit-breakers.
  • Long Mechanical Life: Designed for 10,000 mechanical operations ensuring long-term reliability.
  • Flexible Installation: Mounts on standard 35mm DIN rail with fast clip device for easy setup.
  • Fast Delivery: Standard delivery time is 25 days for efficient project scheduling.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)

Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N) pictures & photos
Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N) pictures & photos
Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N) pictures & photos
Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N) pictures & photos
Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N) pictures & photos
Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N) pictures & photos
Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
  • Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
  • Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
    Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
  • Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
    Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
  • Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
    Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
  • Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
    Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
  • Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
    Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
  • Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
    Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)

Find Similar Products

Product Description

Product Description

 DZ40LE-63  RCCB RCCB/RCBO/ELCB /RCD 2P 4P 30ma 40A 63A Earth Leakage Magnetic Safer Leakage Protection  
Electromagnetic type residual current circuit-breakers (RCCB operating function independent of line voltage) applies to the electrical circuit which alternating current 50/60Hz,rated voltage 230V (1P+N), rated current 63A. When human get an electric shock or electric leakage current exceeds specified value, RCCB can switch off fault power source within 0.1S (1*I△n) quickly, protects human body and electric equipment safety, also can be used to switch on and switch off circuit infrequently.
Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)

Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)

SPECIFICATIONS

 

 

  Standard  Unit IEC/EN 61009-1

Electrical

features

Mode    Electro-magnetic type ,electronic type
Type(wave form of the earth leakage sensed)   A, AC
Thermo-magnetic release characteristic   B,C,D
Rated current ln A 6,10,16,20,25,32,40,63
Poles P 1P+N, 2P
Rated voltage Ue V AC 230, 400
Rated sensitivity I△n A 0.01, 0.03, 0.1, 0.3, 0.5
Rated residual making and breaking capacity l△m A 500
Rated short-circuit capacity Icn A 6000
Break time under I△n S ≤0.1
Rated frequency Hz 50/60
Rated impulsewithstand voltage(1.2/50)Uimp V 4000
Dielectric test voltage at ind.Freq for 1min kV 2
Insulation voltage Ui V 250
Pollution degree   2

Mechanical

features

Electrical life   4000
Mechanical life   10000
Fault current Indicator   YES

Protection degree

 

IP20

Ambient temperature

(with daily average≤35ºC)

ºC

-5~+40(Special application please refer to

temperature compensation correction)

Storage temperature ºC -25~+70
Installation Terminal connection type   Cable/Pin-type busbar/U-type busbar
Terminal size top/bottom for cable mm2 25
AWG 18-5
Terminal size top/bottom for busbar mm2 25
AWG 18-3
Mounting   On DIN rail EN 60715(35mm)by means of fast clip device
Connection   From top


Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)

 

Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)
Our Services:
 

  1. Competitive price
  2. Continuance Service and support
  3. Good-after service
  4. Quality Reliability and Long Product Life.

  Earth Leakage Current Circuit Breaker RCBO ELCB Electromagnetic 2p (1P+N)

About the Supplier

Watch Video
Watch Video
Wenzhou Santuo Electrical Co., Ltd.
Wenzhou Santuo Electrical Co., Ltd.
Wenzhou Santuo Electrical Co., Ltd.
Wenzhou Santuo Electrical Co., Ltd.
Wenzhou Santuo Electrical Co., Ltd.
Wenzhou Santuo Electrical Co., Ltd.
Wenzhou Santuo Electrical Co., Ltd.
Wenzhou Santuo Electrical Co., Ltd.

About Our Factory & Business Background

Address
No. 3999 Liujiang Road, Liushi Yueqing, Wenzhou, China.
Terms of Payment
LC, T/T, D/P, PayPal
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays
Nearest Port
NINGBO

Our Production Capability & Technical Expertise

Main Products
Circuit Breaker, AC Contactor, Thermal Relay, Magnetic Starter, Switch, Industrial Plug, Motor and Mechnism of Acb, Power Distribution Case, Voltage Regulator, Push Button Switch

Our Industry Experience & Global Business Record

Export Year
2016-01-08
Main Markets
South America, Eastern Europe, Southeast Asia, Africa, Mid East, Eastern Asia, Western Europe

FAQ

What is the response time for fault detection?
The device switches off the fault power source within 0.1 seconds when the leakage current exceeds the specified value.
What rated currents are available?
Rated currents range from 6A, 10A, 16A, 20A, 25A, 32A, 40A to 63A.
What are the available pole configurations?
The product is available in 1P+N and 2P configurations.
What is the maximum short-circuit capacity?
The rated short-circuit capacity is up to 6000A.
How long is the mechanical life of the breaker?
The mechanical life is rated for 10,000 operations.
What is the standard delivery time?
The standard delivery time is 25 days.
What standards does this product comply with?
It complies with the IEC/EN 61009-1 standard.
What is the rated impulse withstand voltage?
The rated impulse withstand voltage is 4000V (1.2/50).

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now