Product Highlights

  • High Breaking Capacity: Up to 70kA ultimate short circuit breaking capacity for reliable protection.
  • Wide Current Range: Available in rated currents from 63A to 630A with multiple frame sizes.
  • IEC and GB Compliant: Meets IEC 60947-2 and GB14048.2 standards for safety and performance.
  • Versatile Pole Options: Supports 2P, 3P, and 4P configurations for diverse circuit needs.
  • Long Product Life: Designed for reliability with high endurance and long service life.
  • Air Arc Extinguishing: Utilizes air as the arc-extinguishing medium for safe operation.
  • Fixed Installation: Optimized for fixed installation in power distribution systems.
  • Multi-Function Protection: Provides overload, short circuit, and failure protection for electrical equipment.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Sts3 100A Module Case Circuit Breaker Overload Protection MCCB

Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
Sts3 100A Module Case Circuit Breaker Overload Protection MCCB pictures & photos
Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
Sts3 100A Module Case Circuit Breaker Overload Protection MCCB pictures & photos
Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
Sts3 100A Module Case Circuit Breaker Overload Protection MCCB pictures & photos
Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
Sts3 100A Module Case Circuit Breaker Overload Protection MCCB pictures & photos
Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
Sts3 100A Module Case Circuit Breaker Overload Protection MCCB pictures & photos
Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
Sts3 100A Module Case Circuit Breaker Overload Protection MCCB pictures & photos
Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
  • Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
  • Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
    Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
  • Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
    Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
  • Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
    Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
  • Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
    Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
  • Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
    Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
  • Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
    Sts3 100A Module Case Circuit Breaker Overload Protection MCCB

Find Similar Products

Product Description

Product Description

GENERAL

STS3 Moulded case ciecuit breaker is suitable for circuit AC 50HZ/60HZ, rated voltage up to AC 660V,rated operating current to 630A.It features normal structure,reliable performance,compete accessories & high breaking capacity, used foe power distribution and protecting the circuit and electrical equipment against overload and short circuit. It complies with standard of IEC 60947-2 and GB14048.2

Specifications
Frame size rated current(A) Circuit rated current Rated current at N-pole Frame size rated current Circult rated current Rated current at N-pole
63 10 10 225 100 100
16 16 125 100
20 20 160 100
25 25 180 100
32 32 200 100
40 40 400 225 125
50 50 225 225
63 63 250 225
100 25 25 315 225
32 32 350 250
40 40 400 250
50 50 400 250
63 63 630 500 315
80 63 630 350
100 63    
 

Molded Case Circuit Breaker Specification:

Type Rated current (A) Num-ber of Poles Rated insulation voltage(V) Rated operating voltage(V) Overall Dimensions Ultimated short Circuit Breaking Capacity(KA) Service Short Circuit Breaking Capacity(KA)

Operation performance

(Endurance)

L W(3P/4P) H

AC380V   AC660V

 (400)       (690)

AC380V   AC660V

 (400)       (690)

Load Unload
STS3-125E

12.5,16,20,

25,32,40, 50,

63,80,125,100

2P

3P/4P

660V

380

660

120 76/101 70  15             - 7.5             - 3000 7000
STS3-125S 25             - 16              -
STS3-160S

16,20,32,40,50,

63,80,100,125,

160

2P

3P/4P

660V

380

660

120 90/120 70 35            8 18              - 4000 6000
STS3-160H 50            10 25              -
STS3-250S

100,125,160,

180,200,225,

250

 

2P

3P/4P 

 660V  

380

660

170 105/140 103.5   36            10 18              - 2000   6000  
STS3-250M 60            16 30              -
STS3-250H 65            18 48              -
STS3-800S

500,630,700,

800

2P

3P/4P

660V    380

660

268 210/280 103.5   50            20 30              - 1000  4000  
STS3-800M 65            25 48              -
STS3-800H 80            30 60              -
STS3-400S

200,225,250,300,

300, 400

2P

3P/4P

660V

380

660

254 140/184 103.5 35            16 18              - 1000 4000
STS3-400M 50            20 30              -
STS3-400H 65            25 48              -
STS3-630S 400, 500, 600

2P

3P/4P

660V

380

660

268 210/280 103.5 50            20 30              - 1000 4000
STS3-630M 65            25 48              -
STS3-630H 80            30 60              -

 

Molded Case Circuit Breaker Tripping Characteristics:

Rated current of release (A) Thermodynamic release (ambient temp+40) Operational currentof magnetic release (A)

1.05In(cold state) 

inoperative time (h)

 

1.30In(heat state)inoperative time(h)
In<63 ≥1 <1 10-50In±20%
63<In<100 ≥2 <2 10In±20%
100<In<630  ≥2 <2 5-10In±20%
Rated current of release (A) Thermodynamic release(ambient temp+40ºC)  

1.0In

(cold state)
inoperative time

1.20In

(heat state)
operative time

1.50In

(heat state)
operative time

7.2In

(heat state)
operative time

Operational current
of magnetic
release (A)
12.5<In<400 ≥2h <2h <4min 2S<Tp<10s 12In±20%
Sts3 100A Module Case Circuit Breaker Overload Protection MCCB
Sts3 100A Module Case Circuit Breaker Overload Protection MCCBSts3 100A Module Case Circuit Breaker Overload Protection MCCBSts3 100A Module Case Circuit Breaker Overload Protection MCCB
Our Services:
 
  1. Competitive price
  2. Continuance Service and support
  3. Good-after service
  4. Quality Reliability and Long Product Life.

 

Sts3 100A Module Case Circuit Breaker Overload Protection MCCB

About the Supplier

Watch Video
Watch Video
Wenzhou Santuo Electrical Co., Ltd.
Wenzhou Santuo Electrical Co., Ltd.
Wenzhou Santuo Electrical Co., Ltd.
Wenzhou Santuo Electrical Co., Ltd.
Wenzhou Santuo Electrical Co., Ltd.
Wenzhou Santuo Electrical Co., Ltd.
Wenzhou Santuo Electrical Co., Ltd.
Wenzhou Santuo Electrical Co., Ltd.

About Our Factory & Business Background

Address
No. 3999 Liujiang Road, Liushi Yueqing, Wenzhou, China.
Terms of Payment
LC, T/T, D/P, PayPal
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays
Nearest Port
NINGBO

Our Production Capability & Technical Expertise

Main Products
Circuit Breaker, AC Contactor, Thermal Relay, Magnetic Starter, Switch, Industrial Plug, Motor and Mechnism of Acb, Power Distribution Case, Voltage Regulator, Push Button Switch

Our Industry Experience & Global Business Record

Export Year
2016-01-08
Main Markets
South America, Eastern Europe, Southeast Asia, Africa, Mid East, Eastern Asia, Western Europe

FAQ

What is the rated voltage range?
The circuit breaker supports AC 50HZ/60HZ with a rated voltage up to AC 660V.
What are the available current ratings?
Rated operating currents range from 63A to 630A, including specific models like 100A, 225A, and 630A.
Does it support customization?
Yes, standard options include IEC 60947-2 and GB14048.2, with coil voltages of AC 400V or AC 690V.
What is the maximum breaking capacity?
The ultimate short circuit breaking capacity reaches up to 70kA depending on the specific model.
What certifications does it hold?
The product is CE certified and complies with international standards IEC 60947-2 and GB14048.2.
What are the lead times for orders?
Peak season lead time is 1-3 months, while off-season lead time is within 15 workdays.
What payment terms are accepted?
Accepted payment terms include LC, T/T, D/P, and PayPal.
Is technical support available?
Yes, we provide competitive pricing, continuous service, and good after-sales support.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now