• Residual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing Chart
  • Residual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing Chart
  • Residual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing Chart
  • Residual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing Chart
  • Residual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing Chart
  • Residual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing Chart

Residual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing Chart

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: High-Speed Circuit Breaker
Samples:
US$ 100/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Residual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing Chart pictures & photos
Residual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing Chart
US $53.25 / Piece
Min. Order: 100 Pieces
Diamond Member Since 2017

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Product Description
  • FAQ
Overview

Basic Info.

Model NO.
STRO1-40L
Arc-extinguishing Medium
Air
Installation
DIN Rail
Structure
ELCB
Poles Number
4
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
CE
Standard
IEC 61008
Ue
230/400V
in
16, 25, 32, 40, 63A
Pole
2p 4p
Certificate
CE, CB
Transport Package
Inner Box/Carton
Specification
100pcs/ctns
Trademark
SONTUOEC, WZSTEC
Origin
Wenzhou Zhejiang
HS Code
8536200000
Production Capacity
2000pieces/Day

Packaging & Delivery

Package Size
46.00cm * 24.00cm * 33.00cm
Package Gross Weight
0.025kg

Product Description

Product Description

These series RCBO 1P+N in the line of AC 50HZ, rated voltage 230V and rated current up to 40A to automatically and immediately cut off power supply once someone suffers from electric shock or leakage current above specified value. It can effectively protect personal security and avoid the damage to equipments.The circuit-breaker can also function as overload and shortcircuit protection and unfrequent changeover of line under normal condition.
The product is conformity with GB16917.1,IEC61009-1 standards.

 

Normal working & installment conditions:
1.Ambient temperature: -5ºC~+40ºC, 24 hours average temperature not exceed +35ºC.
2.Installment plance altitude: ≤2000m
3.Gas relative humidity:not exceed 50% at +40ºC, higher humidity allowed at lower temperature.
4.Pollution degree: 2 class
5.Installment condition: Mounted in the place without obvious impact or shock, no dangerous(explosion) dielectric without corrosive metal or damaging isolation gas(conductive dust).
6.Installment method: TH35-7.5 mounted rail, can be installed in distribution board, case or box. Generally mounted vertically. Tilted angle between mounting face and vertical face not exceed ±5°.
7.Mounted Category: II,III class.

8.Comply with Southern Market or Middle East Market.

Technical data:

Standard  IEC61009  (Electronic type)
Breaking Capacity 4.5KA, 6KA 
Number of poles 1P+N(1 module)
Rated currents 6,10,16, 20, 25, 32, 40A
Rated voltage 110/220VAC
Rated Tripping Current 10mA,30mA, 100mA,300mA
Residual current off time ≤0.1s
Characteristic B ,C
Electrical endurance 10000
Mechanical endurance 20000
Ambient temperature -25ºC~+45ºC Max. 95%humdity
Connection terminal Fexibe conductor 16mm²
Rigid conductor 25mm²
Type of terminal Plug-in  type
Width 18mm /module

 

Residual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing ChartResidual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing ChartResidual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing ChartResidual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing ChartResidual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing ChartResidual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing Chart

FAQ

Q 1. what's the payment term?   
A. We accept TT,30% deposit and 70% balance agaisnt copy of BL
Q 2. how's the delivery time ? 
A. usually it will take about 25 days for production
Q 3. tell me the standard of package?   
A. Normally are cartons, but also we can pack it according to your requirement.
Q 4.Would you accept to use our logo ? 
A.If you have good quantity,it absolute no problem to do OEM.
Q5. Can i take some samples?
A: Yes, we support to take samples before place the order. Just feel free to contact with us if you have any requirements.
Q6. Are you original Factory?
A: Yes, we have our own factory .
Q7. How can you make sure the quality of the products?
A: We will accord to international quality standards to inspect every item before leaving our factory.
Residual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing Chart

Thanks for your reading.If any product meets your need.Welcome to send us an email.We are sure your any information can be attentioned without any delay.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Residual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing Chart pictures & photos
Residual Current Circuit Breaker Outlet Motor Circuit Breaker Sizing Chart
US $53.25 / Piece
Min. Order: 100 Pieces
Diamond Member Since 2017

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Management System Certification
ISO 9001
Terms of Payment
LC, T/T, D/P, PayPal