ELCB AC 4p 63A 30mA Leakage RCD Residual Current Circuit Breaker RCCB

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 100/Bag
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
Terms of Payment
LC, T/T, D/P, PayPal
  • ELCB AC 4p 63A 30mA Leakage RCD Residual Current Circuit Breaker RCCB
  • ELCB AC 4p 63A 30mA Leakage RCD Residual Current Circuit Breaker RCCB
  • ELCB AC 4p 63A 30mA Leakage RCD Residual Current Circuit Breaker RCCB
  • ELCB AC 4p 63A 30mA Leakage RCD Residual Current Circuit Breaker RCCB
  • ELCB AC 4p 63A 30mA Leakage RCD Residual Current Circuit Breaker RCCB
  • ELCB AC 4p 63A 30mA Leakage RCD Residual Current Circuit Breaker RCCB
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
STID-63
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Air
Installation
DIN Rail
Structure
ELCB
Poles Number
4
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CB
Standard
IEC 61008
in
16, 25, 32, 40, 63, 80, 100, 125A
Ue
230/400V
Pole
2p, 4p
Leakage Current
10mA, 30mA, 100mA, 300mA, 500mA
Price
Factory Price
Max Current
125A
Connect Wire
Big Screw Hole Size
Warranty Time
12months
Transport Package
Inner Box/Carton
Specification
100pcs/ctns
Trademark
SONTUOEC, WZSTEC, STUOEC, SONTUOC
Origin
Wenzhou, China
HS Code
853620000
Production Capacity
2000pieces/Day

Packaging & Delivery

Package Size
46.00cm * 24.00cm * 33.00cm
Package Gross Weight
0.025kg

Product Description

Product Description

 

ELCB AC 4P 63A 30mA Leakage RCD Residual Current Device Circuit Breaker ID series 85% siliver point red copper parts IEC61008.1 RCCB:

STID-63 (ID)series residual current circuit breaker is in conformity with the standards of IEC61008.It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunkline.Thus it is suitable to avoid the shock hazard and fire caused by earth leakage.It can be used in circuits up to single phase 230V,three phase 400V,50 or 60Hz.
  • Model: Electro-magnetic type; Electronic type
  • Residual current characteristics: A, AC
  • Pole No.: 2P, 4P
  • Rated making and breaking capacity: 630A
  • Rated current: 16A, 25A, 32A, 40A, 63A; 80A, 100A,125A
  • Rated voltage: 230/400V AC
  • Rated frequency: 50/60Hz
  • Rated Residual Operating Current IΔn:10mA, 30mA, 100mA, 300mA, 500mA
  • Rated Residual Non-operating Current I Δno:  ≤0.5IΔn
  • Rated conditional short-circuit current Inc: 6000A
  • Rated conditional residual short-circuit current IΔc: 6000A
  • Tripping duration: Instantaneous tripping ≤0.1Sec
  • Residual tripping current range: 0.5IΔn~IΔn
  • Electro-mechanical endurance: 4000 Cycles
  • Fastening torque: 2.0Nm
  • Connection terminal:Screw terminal
    Pillar terminal with clamp
  • Installation:35mm Din rail mounting

Specifications

Electrical
Feature
Standard   IEC61008-1
Type(wave form of the earth leakage sensed)   AC,A 
Rated current In A 16,25,32,40,63 
Poles P 2,4
Rated voltage Ue V 230/400
Rated sensitivity I n A 0.01,0.03,0.1,0.3
Insulation voltage Ui V 500
Rated residual making and A 630
breaking capacity I m    
Short-circuit current I c A 4500/6000
SCPD fuse A 6000
Break time under I n s <0.1
Rated frequency Hz 50/60
Pollution degree   2
MechanicaI
features
Electrical life t 4000
MechanicaI Iife t 20000
Fault current indicator   Yes
Protection degree   IP20
Ambient temperature C From -25C untill 40C
(with daily average 35 )    
Storage temperature C From -25C untill 70C

ELCB AC 4p 63A 30mA Leakage RCD Residual Current Circuit Breaker RCCBELCB AC 4p 63A 30mA Leakage RCD Residual Current Circuit Breaker RCCBELCB AC 4p 63A 30mA Leakage RCD Residual Current Circuit Breaker RCCBELCB AC 4p 63A 30mA Leakage RCD Residual Current Circuit Breaker RCCBELCB AC 4p 63A 30mA Leakage RCD Residual Current Circuit Breaker RCCB1.Provide protection against earth fault/leakage current and function of isolation

2.High short-circuit current withstand capacity

3.Applicable to terminal and pin/fork type busbar connection

4. Equipped with finger protected connection terminals

5.Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity

6.Independent of power supply and line voltage, and free from external interference, voltage fluctuation.   ----------  Big size connection wire ( 35mm connection cable)

FAQ
Q 1. what's the payment term?   
A. We accept TT,30% deposit and 70% balance agaisnt copy of BL
Q 2. how's the delivery time ? 
A. usually it will take about 25 days for production
Q 3. tell me the standard of package?   
A. Normally are cartons, but also we can pack it according to your requirement.
Q 4.Would you accept to use our logo ? 
A.If you have good quantity,it absolute no problem to do OEM.
Q5. Can i take some samples?
A: Yes, we support to take samples before place the order. Just feel free to contact with us if you have any requirements.
Q6. Are you original Factory?
A: Yes, we have our own factory .
Q7. How can you make sure the quality of the products?
A: We will accord to international quality standards to inspect every item before leaving our factory.


ELCB AC 4p 63A 30mA Leakage RCD Residual Current Circuit Breaker RCCB
WENZHOU SANTUO ELECTRICAL CO,LTD.
  :
  is one of manufactories that specialize in manufacturing AC CONTACTOR, Thermal Relay and Circuit Breaker, Distribution Case, Solid State Relay,Voltage Regulator and is located in Liushi.Wenzhou.China 


ELCB AC 4p 63A 30mA Leakage RCD Residual Current Circuit Breaker RCCB
Thanks for your reading.If any product meets your need.Welcome to send us an email.We are sure your any information can be attentioned without any delay.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier