• 2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type
  • 2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type
  • 2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type
  • 2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type
  • 2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type
  • 2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type

2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: High-Speed Circuit Breaker
Samples:
US$ 100/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type pictures & photos
2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type
US $53.25 / Piece
Min. Order: 500 Pieces
Diamond Member Since 2017

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
STB4-63LE
Arc-extinguishing Medium
Air
Installation
DIN Rail
Structure
ELCB
Poles Number
4
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
CE, CB
Standard
IEC/En62423;IEC/En61008-1
Ue
230/400V
in
16,25,32,40,63A
Pole
2p 4p
Transport Package
Inner Box/Carton
Specification
100pcs/ctns
Trademark
SONTUOEC, WZSTEC
Origin
Wenzhou Zhejiang
HS Code
8536200000
Production Capacity
1000pieces/Day

Packaging & Delivery

Package Size
46.00cm * 24.00cm * 33.00cm
Package Gross Weight
0.500kg

Product Description

Product Description

B Type Rccb Residual Current Circuit Breaker Electro-magnetic using charging station for electric vehicle

General:

STB2-63LE(Electronic model) , STID-B (Magnetic model) RCCB B type is worked on type A and in addition for smooth DC residual currents, residual DC currents that may results from rectifying circuits and high frequency AC residual currents.It protects in the event of contunuous fault current on three phase networks. It usually is used in the field of Recharging Station, Medical Apparatus and Instruments, Controllers and Variable Speed Drives, Batter Charges and Inverters(DC)...STID-B complys with IEC/EN61008 and IEC/EN62423 standards.PRODUCT PARAMETERS

Modle
STB2-63LE; STID-B 
STB4-63LE; STID-B 
Poles
                   1P+N/2P 
 3P+N/4P
Rated Current(A)
16A-63A
16A-63A
Rated Frequency(Hz)
50/60Hz
50/60Hz
Rated Working Voltage(V)
230/400V
230/400V
Rated Breaking Capacity(A)
4500A
6000A
Instantaneous Tripping Type
B,C
B,C
Certification
CE   
CE   CB

2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type
2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type
Model: B

Rated current: 16,25,32,40,50,63A

Pole: 2P, 4P

Electrical life: 2000 times

Mechanism life: 10000times

Ambient Temperature:-40~ +55 C

Storage temperature: -40~ +70 C

Protection Degree: IP20

Short circuit breaking capacity: 6KA, 10KA

Mounting: Din rail En60715(35mm)

Tightening torque: 2.5N*M

Approvals: CE,CB, SAA, ISO9001; If needed, we can provide testing report and Approvals for your reference.

2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type

 

2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type
FAQ:

Q: Are you trading company or manufacturer ?

A: We are factory. Our teams have more than 20years experience in the field of Circuit Breaker...

Q: How long is your delivery time?

A: Usually, normal orders need 25days or so.

Q: Do you provide samples ? is it free or extra ?

A: Yes, we could offer the sample for free charge,but,the express charge need be paid by the buyers.

Q: What is your terms of payment ?

A: Payment<=5000USD, 100% in advance. Payment>=5000USD, 30% T/T in advance ,balance before shippment.

2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type pictures & photos
2p 4p Residual Current Circuit Breaker Electric Leakage Protection RCCB B Type
US $53.25 / Piece
Min. Order: 500 Pieces
Diamond Member Since 2017

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Management System Certification
ISO 9001
Terms of Payment
LC, T/T, D/P, PayPal