Water Proof Alarm and Over/Down Voltage Protection Type Multi Functional Circuit Breaker (RCBO)
Contact Supplier
Product Highlights
- Multi-functional intelligent digital display, with customizable and adjustable parameters
- Multi-layered global electrical protection, ensuring maximum safety performance
- Full specification coverage, compatible with single-phase/three-phase multiple scenarios
Product Attributes
- Customization
- Available
- Breaking Capacity
- Low Voltage Circuit Breakers
- Operation
- Manual Type
- Model NO.
- STRO7-63
- Speed
- High-Speed Circuit Breaker
- Arc-extinguishing Medium
- Air
- Installation
- Fixed
- Structure
- ELCB
- Poles Number
- 4
- Type
- Circuit Breaker
- Function
- Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
- Certification
- ISO9001-2000, CE
- Standard
- IEC61009.1,GB16917.1
- in
- 16,25,32 ,40, 63,80,100
- Ue
- 230/400V
- Pole
- 2p+PE; 4p+PE
- Rated Sensitivity
- 30,100 Ma
- Transport Package
- Inner Box/Carton
- Specification
- 100pcs/ctns
- Trademark
- SONTUOEC, WZSTEC, SONTUNE, IMDEC
- Origin
- Wenzhou Zhejiang
- HS Code
- 8536200000
- Production Capacity
- 2000pieces/Week
- Package Size
- 46.00cm * 24.00cm * 33.00cm
- Package Gross Weight
- 0.025kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of Water Proof Alarm and Over/Down Voltage Protection Type Multi Functional Circuit Breaker (RCBO)
Find Similar Products
Product Description
GENERAL
STRO7-63/100 (STFS2-100) Series Multi function residual current circuit breaker with over current protection(RCBO)is suitable for AC 50/60Hz,
rated in a circuit with a voltage of 230V-400V and a rated current of 100A,when a person is electrocuted or the power grid leaks..
When the leakage,overvoltage,and undervoltage reach the set values,the residual current circuit breaker can quickly operate in a very short period of time quickly cut of the power supply.When the monitoring temperature of the residual current circuit breaker reaches the set value,the monitoring ground wire is not connected.
When connected,the product emits an alarm sound to protect the safety of personnel and electrical equipment,
and can avoid Prevent damage to equipment caused by overvoltage in the power grid.It has overload,short circuit,leakage,
overvoltage, undervoltage and overtemperature protection functions can also be used to intermittently turn on and off electrical
devices under normal circumstances lighting circuits,especially suitable for industrial and commercial lighting distribution systems.
The product has a small volume,compact structure,and better cost effectiveness than other similar products.It has a beautiful
appearance,high breaking capacity makesit a good choice for household power distribution.This product complies with
GB/T 16917.1 and IEC61009-1 standards and has obtained CE certification.
SPECIFICATIONS:
| Standard | Unit | IEC/EN 61009-1 | |
|
Electrical features |
Mode | Electronic type | |
| Type(wave form of the earth leakage sensed) | AC | ||
| Thermo-magnetic release characteristic | B,C,D | ||
| Rated current ln | A | 6-100A(6,10,16,20,25,32,40,63;80,100A) Adjustable | |
| Poles | P | 1P+N+PE, 3P+N+PE | |
| Rated voltage Ue | V | AC 230, 400 (Adjustable) | |
| Rated sensitivity I△n | A | 30-300mA(30,100,300mA) Adjustable | |
| Rated residual making and breaking capacity l△m | A | 500 | |
| Rated short-circuit capacity Icn | A | 6000 | |
| Break time under I△n | S | ≤0.1 | |
| Rated frequency | Hz | 50/60 | |
| Rated impulsewithstand voltage(1.2/50)Uimp | V | 4000 | |
| Dielectric test voltage at ind.Freq for 1min | kV | 2 | |
| Insulation voltage Ui | V | 250 | |
| Pollution degree | 2 | ||
| Other | Over/under voltage protection; | and | Temperature Protection ; Fire-alwarm and others |
|
Mechanical features |
Electrical life | 4000 | |
| Mechanical life | 10000 | ||
| Fault current Indicator | YES | ||
|
Protection degree |
IP20 |
||
|
Ambient temperature (with daily average≤35ºC) |
ºC |
-5~+40(Special application please refer to temperature compensation correction) |
|
| Storage temperature | ºC | -25~+70 | |
| Installation | Terminal connection type | Cable/Pin-type busbar/U-type busbar | |
| Terminal size top/bottom for cable | mm2 | 25 | |
| AWG | 18-5 | ||
| Terminal size top/bottom for busbar | mm2 | 25 | |
| AWG | 18-3 | ||
| Mounting | On DIN rail EN 60715(35mm)by means of fast clip device | ||
| Connection | From top |
SURROUNDING AIR TEMPERATURE:
1.The ambient air temperature shall not be lower than -5ºC,not higher than+40ºC,and the daily average value shall
not exceed +35ºC .
2.Altitude:The altitude of the installation site shall not exceed 2000m.
3.Atmospheric conditions
The air is clean,and at a maximum temperature of+40ºC,the relative humidity of the air is not high More than 50%.Higher relative humidity is allowed at lower temperatures,such as at+20ºC,
The relative humidity should not exceed 90%.Due to occasional moderate condensation caused by temperature changes,
attention should be paid to taking appropriate measures.
4.Installation Category :DIN RAIL Installation.
5. Recommended selection principles:
5.1 General selection principles
a)The rated working voltage of RCBO ≥ the rated voltage of the line.
b) The rated current of RCBO is 1.1-1.25 times the load current calculated by the line.
c)The rated short-circuit breaking capacity of RCBO ≥ the maximum short-circuit
current that may appear in the line.
d)RCBO instantaneous release setting current ≤ 0.8 times the end of the line phase
-to-ground or phase-to-phase short circuit current.
e) Single-phase rated current of electric heaters, refrigerators and incandescent la-
mps at a given voltage and power In=P/U; three-phase rated current In=P/1.732U.
RCBO residual current is generally selected as 30mA, which is used as personal
contact protection.
To install and use the product, please read the retention manual.



User's Guide and Function:
Operation Guide for the Multi-Function Residual Current Circuit Breaker (RCBO):
1.Press the SET button to enter the settings interface;
2. OV----Over/Under Voltage (230V-300V) Adjustable: Adjust with up and down keys (V);
3. The interface displays 05-5 (05 indicates the delayed trip time in seconds; 5 denotes a 5% time error);
4. UV---Under Voltage (160V-210V) adjustable; adjust with up/down keys (V); this product also features phase loss protection; if UV occurs on the 3P+N+PE three-phase product, it may be due to phase loss protection; product trips;
5. The interface displays 05-5 (05 indicates the delayed trip time (seconds); 5 represents a 5% time error;
6. OC----Rated current; 63 type (10-63A) adjustable; 100 type (10-100A) adjustable; Adjust with up and down keys (setting);
7. RCD---Leakage Current (30-300mA) Adjustable; Adjust via Up/Down Keys (Setting)
8. The interface displays 05-5 (05 indicates the delayed trip time in seconds; 5 represents a 5% time error;
9. OH---Temperature Protection Parameter (Adjustable between 60-120°C, use up/down keys to set);
10. Leakage current shut-off function: Press and hold the OK button for 3 seconds until the screen turns off. Release the button, and the RCD indicator will flash, indicating the leakage current function is disabled. To restore the leakage current function, press and hold the OK button for 3 seconds until the screen turns off. Release the button, and the RCD indicator will stop flashing, confirming the leakage current function is operational. ```Directly output the translation without explanation, ensuring the semantics are smooth.```
11. After completing the above function settings, press the OK button to save the parameter settings.
12. If the line is submerged in water, the product will emit a beeping alarm but will not trip (the product must be connected to the output PE line);
13. When the PE line input is invalid or not connected, the GFCI indicator on the product screen flashes, the grounding indicator light turns off, the product emits a buzzer alarm, and the product trips for protection.
14. Real-time parameter query function: Press the button to sequentially check the real-time voltage value, phase A, B, and C current values, leakage current value, and temperature value.
15. Notes: The product must strictly adhere to the wiring as indicated on the product. L -- live wire; Line -- input wire; N -- neutral wire; PE -- ground wire
16. 1).This product must be operated by a professional electrician (holding an electrician certificate).
2).All responsibility for safety accidents during installation by non electricians shall be borne by the user.
Warn!
1. This product must be wired and installed by qualified personnel;
2. It is strictly forbidden to operate the leakage circuit breaker with wet hands,
otherwise electric shock accidents may occur;
3. Leakage circuit breakers cannot be used for personal electric shock caused by
simultaneous contact with the two lines of the protected circuit. Protect;
4. When the leakage circuit breaker is used for the action characteristic test, it
should be tested and qualified by the relevant state departments. It is strictly
forbidden to use the test method of directly touching the grounding device or direct
short circuit;
5. It is strictly forbidden to directly test the insulation resistance at the outlet of the
product; the power supply of the electronic circuit board should be disconnected,
And ensure that there is no voltage at the input and output terminals of electronic
components before testing, otherwise the circuit board will be burned electronic co-
mponents;
6. The overload, short circuit and residual current protection characteristics of the
leakage circuit breaker are all set by the manufacturer. It is allowed to disassemble
and adjust at will;
7. After the leakage circuit breaker is opened due to the failure of the protected circuit
(leakage, overload or short circuit, etc.), The reason must be
found out, and the closing operation can only be performed after troubleshooting:
8. It is strictly forbidden to connect the load when the leakage circuit breaker is closed:
9. During use, there should be no phase failure or "N" wire disconnection on the power
supply side. Wiring, this product cannot play the role of leakage protection.
Precautions!
1. Leakage circuit breakers must not be attacked by rain or snow during transportation,
storage and use.
2. Before installation, check whether the basic technical data of the signs and signs
meet the requirements (the selected current The size should match the actual use):
manual operation several times should be flexible, confirm that it is intact, Installation:
When installing, wires that can withstand the corresponding current carrying capacity
should be selected. See attached table 3 for reference values.
3. Strictly follow the wiring diagram for installation.
4. Run check: 4.1 Check whether the wiring is correct, especially check that the
input terminal of the leakage circuit breaker should be connected to the power supply,
and the output terminal should be connected to the load.
4.2 Confirm that the screws of each terminal have pressed the wire tightly, and the wire
should be in the corresponding wiring frame.
4.3 Close the leakage circuit breaker and press the test button to check whether the
leakage protection performance is normal and reliable. If the leakage circuit
breaker can be disconnected normally, the indicator will be red.
5. After the leakage circuit breaker has been running for a certain period of time
(usually one month), it is necessary to press the test button in the closed and energ-
ized state to check whether the leakage protection performance is normal andreli-
able (press the test button once a month, and the leakage circuit breaker should be
broken once). In case of failure, it should be removed and sent to the manufacturer
for repair.
6. The neutral wire () at the outlet end can only be used as a working neutral wire, not
a protective neutral wire. 7. When the leakage exitable model is selected, the leakage
"exit" function of the circuit breaker is an emergency use function, which is only used
by professional power supply maintenance personnel in emergency maintenance situations.
After maintenance, it must be put into leakage protection function status immediately.
Product Over View:
1.Provide protection against earth fault/leakage current and function of isolation
2.High short-circuit current withstand capacity
3.Applicable to terminal and pin/fork type busbar connection
4. Equipped with finger protected connection terminals
5.Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity6.Independent of power supply and line voltage, and free from external interference, voltage fluctuation.
Our Services:
- Competitive price
- Continuance Service and support
- Good-after service
- Quality Reliability and Long Product Life.
Q1. What advantages do you have?
A1. We are the direct Manufacturer in Wenzhou China , we have professional,our teams have more than 20years experience in the field.Q2. What's your main product?
A2. Circuit Breaker(MCB,RCCB/RCD, RCBO,ELCB, MCCB, ACB); Ac Contactor, Thermal Relay, Magnetic Starter; Isolator Switch, Changeover Switch, Push Button Switch, Voltage Protector...
Q3. Could you print our own logo?
A3. Yes, Our company are available for Retail & Wholesale & OEM & ODM.
Q4. How long is the quality guarantee?
Q5. How long is the deliver time?
Q6. What is your payment terms?
Q7. Any certification of your company or product?
A7.We have ISO 9001, CE, CB, SEMKO, SAA, TUV.
About the Supplier
Company Profile
WENZHOU SANTUO ELECTRICAL Co., Ltd. is one of manufactories that specialize in manufacturing Circuit Breaker; AC CONTACTOR, Thermall Relay and Isolator Switch, Change over switch; Power Distribution Case, Push Button Switch; Voltage Regulator/Protector...More than 20years and is located in Liushi, Wenzhou, China that called " the Capital of Low Voltage Electronic Products", enjoying convenient transportation access and a beautiful environment. Our teams have more than 20years' experience; We have passed ISO9001 approval, The products have passed CE, CB(IEC), SAA certificates and strictly comply with IEC standards. The company has advanced detection instruments and strong technical force with strong research and development capability, product constantly updated. The products export Europe, Asia, Southern Amercia, Middle East, Western Africa market.
If you are interested in any of our products or would like to discuss a custom order, please feel free to contact us. We are looking forward to forming successful business relationships with new clients around the world in the near future.
On the base of guarrantee the quality, we will try our best to design new model with ourselves patents for the coming years.
About Our Factory & Business Background
- Address
- No. 3999 Liujiang Road, Liushi Yueqing, Wenzhou, China.
- Terms of Payment
- LC, T/T, D/P, PayPal
- International Commercial Terms(Incoterms)
- FOB, EXW, CFR, CIF
- Average Lead Time
-
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays - Nearest Port
- NINGBO
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2016-01-08
- Main Markets
- South America, Eastern Europe, Southeast Asia, Africa, Mid East, Eastern Asia, Western Europe
FAQ
- Can the leakage current of this smart circuit breaker be adjusted? What is the adjustment range?
- Adjustable, with a leakage action current adjustable range of 30mA~300mA. Parameter settings can be completed through the SET, up and down arrow, and OK buttons on the right side of the device body; 30mA is suitable for personal electric shock protection, while the high current setting can be used for equipment leakage protection against fire.
- What power supply lines are suitable for the 2P and 4P models respectively, and are there any differences in voltage specifications?
- The 2P model is a single-phase 230V device, designed for household 220V single-phase lighting and socket circuits; the 4P model is a three-phase 400V device, suitable for three-phase power equipment in factories and shops, as well as photovoltaic three-phase power distribution. Both specifications come with PE grounding monitoring terminals.
- What do the RUN and ERR indicator lights on the panel represent respectively, and how to diagnose faults?
- The constant green light of RUN indicates normal operation of the circuit; the ERR light indicates a fault, which can be categorized as leakage, overload, poor grounding, or abnormal voltage; by referring to the LCD screen, specific fault codes can be viewed to quickly locate circuit issues.
Send your message to this supplier
People who viewed this also viewed
-
US$75.00-80.00 / Piece
-
US$0.75-0.76 / Piece
-
US$2.15-2.25 / Piece
-
US$3.82-3.95 / Piece
-
US$75.00-80.50 / Piece
-
US$17.80-18.00 / Piece
Product Groups
- RCBO Circuit Breaker
- Adjustable earth leakage circuit breaker
- Residual current circuit breaker
- Miniature circuit breaker
- Moulded case circuit breaker
- Motor Protection Circuit Breaker
- AC Contactor
- Magnetic Contactor
- Air Conditioning Contactor
- Thermal relay
- Solid State Relay
- Magnetic starter
Find Similar Products By Category
- Supplier Homepage
- Products
- Residual current circuit breaker
- Residual Current Circuit Breaker With Over Current Protectio
- Water Proof Alarm and Over/Down Voltage Protection Type Multi Functional Circuit Breaker (RCBO)
Related Categories
Hot Searches
- Circuit Breaker Factories
- Electric Circuit Breaker Factories
- Vacuum Circuit Breaker Factories
- Miniature Circuit Breaker Factories
- Rcbo Breaker
- New Rcbo
- Leakage Current Circuit Breaker
- Electrical Rcbo
- Rcbo Residual Circuit Breaker
- Circuit Breaker Trends
- Multi Functional Circuit Breaker RCBO Bulkbuy