• Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka
  • Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka
  • Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka
  • Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka
  • Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka
  • Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka

Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Samples:
US$ 100/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka pictures & photos
Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka
US $0.79-0.82 / Piece
Min. Order: 1,000 Pieces
Diamond Member Since 2017

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
STM3-63
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
MCB
Poles Number
4
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE
Standard
IEC 60898.1
Ue
230/400V
in
1,2,4,6,10,16,20,25,32,40,50,63A
Installation Type
DIN Rail or Busbar Type
Price
Factory Price
Inside Design
C65 Design
Transport Package
Exporting Carton
Specification
240pcs/ctns
Trademark
SONTUOEC, WZSTEC, SONTUNE, IMDEC
Origin
Wenzhou Zhejiang
HS Code
8536200000
Production Capacity
2000pieces/Week

Packaging & Delivery

Package Size
46.00cm * 24.00cm * 33.00cm
Package Gross Weight
0.010kg

Product Description

Product Description

Sontune Series 6ka STM3-63 MCB  230V 400V for protecting cables and equipments overload and short circuit 

General

STM3-63 is of high current limiting performance to limit the destruction energy due to short circuit to the greatest extent, which is used in AC50/60Hz, rated voltage of 230V/400V, rated current 1A to 63A for overload and short-circuit protection as well as for unfrequented switching under normal case. It is used extensively for industry, commercial and household. This product conform to IEC60898.1 standard.


Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka



Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka
Specification

  Standard   IEC/EN  60898-1
Electrical
features
Rated current In A 1,2,4,6,10,16,20,25,32,40,50,63
Poles P 1,2,3,4
Rated voltage Ue V AC 230, 400
Insulation voltage Ui V 500
Rated frequency Hz 50/60
Rated breaking capacity A 3500, 4500, 6000
Rated impulse withstand voltage(1.2/50)Uimp V 4000
Dielectric test voltage at ind.Freq.for 1 min Kv 2
Pollution degree   2
Thermo-magnetic release characteristic   B,C,D
Mechanical
features
Electrical life t 4000
Mechanical life t 10000
Protection degree   IP20
Reference temperature for setting
of thermal element
ºC 30
Ambient temperature
(with daily average ≤35ºC)
ºC -5~+40(Special application please refer to
temperature compensation correction)
Storage temperature ºC -25~+70
Installation Terminal connection type   Cable/Pin-type busbar
Terminal size top/bottom for cable mm2 25
AWG 18-3
Therminal size top/bottom for busbar mm2 25
AWG 18-3
Tightening torque N*m 2
In-lbs 18
Mounting   on DIN rail EN 60715(35mm)by means of fast clip device
Connection   From top and bottom

Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka
General rules for choosing MCB
    a. Technical data of the network at the point considered:
      The earthing systems,short-circuit current at the circuit breaker installation point,which must always be less than the breaking capacity of            this device,network normal voltage.
    b. There are 3 curvve characteristics for magnetic operation:
      B curve (3-5In) protection and control of the circuits against length cables in TN and IT systems.
      C curve (5-10In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with           low inrush current.
      D curve (10-14In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with           high inrush current at the circuit closing (LV/LV transformers,breakdown lamps).



About usMarket Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka

 

Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka pictures & photos
Market Tested Cost-Performance Miniature Circuit Breaker DIN Rail Design MCB 6ka
US $0.79-0.82 / Piece
Min. Order: 1,000 Pieces
Diamond Member Since 2017

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Management System Certification
ISO 9001
Terms of Payment
LC, T/T, D/P, PayPal