2p 4p Water Proof Leakage Current Circuit Breaker Multifunction
Contact Supplier
Product Highlights
- Multifunction Protection: Overload, leakage current, temperature, over/under voltage, and OVP protection.
- Water Proof Design: IP20 protection degree ensures safety against rain, snow, and moisture.
- Adjustable Settings: Rated current, leakage current, and temperature settings are adjustable.
- High Breaking Capacity: Rated short-circuit capacity up to 6000A with high withstand capability.
- Wide Current Range: Available in 6A to 100A with 1P+N and 3P+N pole configurations.
- Fast Response Time: Break time under rated sensitivity is less than 0.1 seconds.
- Durable Construction: Electrical life of 4000 cycles and mechanical life of 10000 cycles.
- Certified Quality: Complies with ISO 9001, CE, CB, SEMKO, SAA, and TUV standards.
Product Attributes
- Customization
- Available
- Breaking Capacity
- Low Voltage Circuit Breakers
- Operation
- Manual Type
- Model NO.
- STFS2-100
- Speed
- High-Speed Circuit Breaker
- Arc-extinguishing Medium
- Air
- Installation
- Fixed
- Structure
- ELCB
- Poles Number
- 4
- Type
- Circuit Breaker
- Function
- Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
- Certification
- ISO9001-2000, CE
- Standard
- IEC61009.1,GB16917.1
- in
- 16,20,25,32 ,40; 63,80,100
- Ue
- 230/400V
- Pole
- 4p+PE
- Rated Sensitivity
- 30,100,300mA
- Transport Package
- Inner Box/Carton
- Specification
- 100pcs/ctns
- Trademark
- SONTUOEC, WZSTEC, SONTUNE, IMDEC
- Origin
- Wenzhou Zhejiang
- HS Code
- 8536200000
- Production Capacity
- 2000pieces/Week
- Package Size
- 46.00cm * 24.00cm * 33.00cm
- Package Gross Weight
- 0.350kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of 2p 4p Water Proof Leakage Current Circuit Breaker Multifunction
Find Similar Products
Product Description
The multifunction RCBO has the function of overload,leakage current, temperature protection, rated current/ leakage current /Temperature adjustable;over/under voltage protection;Water proof Protection.
The working reference temperature of RCBO is 30ºC , when the ambient temperature changes, its setting value should be corrected. If multiple RCBOs are installed in a closed box and the temperature inside the box rises, the rated current should be multiplied by the
derating factor of 0.8.
The "N" line on the RCBO should be connected to the neutral line to make the electronic circuit work normally and play a prote- ctive role.
It is not allowed to use the method of short-circuiting the phase line to the neutral line or the phase line to the phase line to carry out the short-circuit protection capability test on the RCBO.
Recommended selection principles
General selection principles
a)The rated working voltage of RCBO ≥ the rated voltage of the line.
b) The rated current of RCBO is 1.1-1.25 times the load current calculated by the line.
c)The rated short-circuit breaking capacity of RCBO ≥ the maximum short-circuit
current that may appear in the line.
d)RCBO instantaneous release setting current ≤ 0.8 times the end of the line phase
-to-ground or phase-to-phase short circuit current.
e) Single-phase rated current of electric heaters, refrigerators and incandescent la-
mps at a given voltage and power In=P/U; three-phase rated current In=P/1.732U.
RCBO residual current is generally selected as 30mA, which is used as personal
contact protection.
To install and use the product, please read the retention manual.





LQB5LE-100 leakage circuit breaker user's Guide:
Warn!
1. This product must be wired and installed by qualified personnel;
2. It is strictly forbidden to operate the leakage circuit breaker with wet hands,
otherwise electric shock accidents may occur;
3. Leakage circuit breakers cannot be used for personal electric shock caused by
simultaneous contact with the two lines of the protected circuit. Protect;
4. When the leakage circuit breaker is used for the action characteristic test, it
should be tested and qualified by the relevant state departments. It is strictly
forbidden to use the test method of directly touching the grounding device or direct
short circuit;
5. It is strictly forbidden to directly test the insulation resistance at the outlet of the
product; the power supply of the electronic circuit board should be disconnected,
And ensure that there is no voltage at the input and output terminals of electronic
components before testing, otherwise the circuit board will be burned electronic co-
mponents;
6. The overload, short circuit and residual current protection characteristics of the
leakage circuit breaker are all set by the manufacturer. It is allowed to disassemble
and adjust at will;
7. After the leakage circuit breaker is opened due to the failure of the protected circuit
(leakage, overload or short circuit, etc.), The reason must be
found out, and the closing operation can only be performed after troubleshooting:
8. It is strictly forbidden to connect the load when the leakage circuit breaker is closed:
9. During use, there should be no phase failure or "N" wire disconnection on the power
supply side. Wiring, this product cannot play the role of leakage protection.
Precautions!
1. Leakage circuit breakers must not be attacked by rain or snow during transportation,
storage and use.
2. Before installation, check whether the basic technical data of the signs and signs
meet the requirements (the selected current The size should match the actual use):
manual operation several times should be flexible, confirm that it is intact, Installation:
When installing, wires that can withstand the corresponding current carrying capacity
should be selected. See attached table 3 for reference values.
3. Strictly follow the wiring diagram for installation.
4. Run check: 4.1 Check whether the wiring is correct, especially check that the
input terminal of the leakage circuit breaker should be connected to the power supply,
and the output terminal should be connected to the load.
4.2 Confirm that the screws of each terminal have pressed the wire tightly, and the wire
should be in the corresponding wiring frame.
4.3 Close the leakage circuit breaker and press the test button to check whether the
leakage protection performance is normal and reliable. If the leakage circuit
breaker can be disconnected normally, the indicator will be red.
5. After the leakage circuit breaker has been running for a certain period of time
(usually one month), it is necessary to press the test button in the closed and energ-
ized state to check whether the leakage protection performance is normal andreli-
able (press the test button once a month, and the leakage circuit breaker should be
broken once). In case of failure, it should be removed and sent to the manufacturer
for repair.
6. The neutral wire () at the outlet end can only be used as a working neutral wire, not
a protective neutral wire. 7. When the leakage exitable model is selected, the leakage
"exit" function of the circuit breaker is an emergency use function, which is only used
by professional power supply maintenance personnel in emergency maintenance situations.
After maintenance, it must be put into leakage protection function status immediately.
Product Over View:
1.Provide protection against earth fault/leakage current and function of isolation
2.High short-circuit current withstand capacity
3.Applicable to terminal and pin/fork type busbar connection
4. Equipped with finger protected connection terminals
5.Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity6.Independent of power supply and line voltage, and free from external interference, voltage fluctuation.
SPECIFICATIONS
| Standard | Unit | IEC/EN 61009-1 | |
|
Electrical features |
Mode | Electronic type | |
| Type(wave form of the earth leakage sensed) | A, AC | ||
| Thermo-magnetic release characteristic | B,C,D | ||
| Rated current ln | A | 6,10,16,20,25,32,40,63;80,100A | |
| Poles | P | 1P+N, 3P+N | |
| Rated voltage Ue | V | AC 230, 400 | |
| Rated sensitivity I△n | A | 0.01, 0.03, 0.1, 0.3, 0.5 | |
| Rated residual making and breaking capacity l△m | A | 500 | |
| Rated short-circuit capacity Icn | A | 6000 | |
| Break time under I△n | S | ≤0.1 | |
| Rated frequency | Hz | 50/60 | |
| Rated impulsewithstand voltage(1.2/50)Uimp | V | 4000 | |
| Dielectric test voltage at ind.Freq for 1min | kV | 2 | |
| Insulation voltage Ui | V | 250 | |
| Pollution degree | 2 | ||
| Other | Over/under voltage protection; | Temperature ; Fire-alwarm | |
|
Mechanical features |
Electrical life | 4000 | |
| Mechanical life | 10000 | ||
| Fault current Indicator | YES | ||
|
Protection degree |
IP20 |
||
|
Ambient temperature (with daily average≤35ºC) |
ºC |
-5~+40(Special application please refer to temperature compensation correction) |
|
| Storage temperature | ºC | -25~+70 | |
| Installation | Terminal connection type | Cable/Pin-type busbar/U-type busbar | |
| Terminal size top/bottom for cable | mm2 | 25 | |
| AWG | 18-5 | ||
| Terminal size top/bottom for busbar | mm2 | 25 | |
| AWG | 18-3 | ||
| Mounting | On DIN rail EN 60715(35mm)by means of fast clip device | ||
| Connection | From top |
Our Services:
- Competitive price
- Continuance Service and support
- Good-after service
- Quality Reliability and Long Product Life.
Q1. What advantages do you have?
A1. We are the direct Manufacturer in Wenzhou China , we have professional,our teams have more than 20years experience in the field.Q2. What's your main product?
A2. Circuit Breaker(MCB,RCCB/RCD, RCBO,ELCB, MCCB, ACB); Ac Contactor, Thermal Relay, Magnetic Starter; Isolator Switch, Changeover Switch, Push Button Switch, Voltage Protector...
Q3. Could you print our own logo?
A3. Yes, Our company are available for Retail & Wholesale & OEM & ODM.
Q4. How long is the quality guarantee?
Q5. How long is the deliver time?
Q6. What is your payment terms?
Q7. Any certification of your company or product?
A7.We have ISO 9001, CE, CB, SEMKO, SAA, TUV.
About the Supplier
Company Profile
WENZHOU SANTUO ELECTRICAL Co., Ltd. is one of manufactories that specialize in manufacturing Circuit Breaker; AC CONTACTOR, Thermall Relay and Isolator Switch, Change over switch; Power Distribution Case, Push Button Switch; Voltage Regulator/Protector...More than 20years and is located in Liushi, Wenzhou, China that called " the Capital of Low Voltage Electronic Products", enjoying convenient transportation access and a beautiful environment. Our teams have more than 20years' experience; We have passed ISO9001 approval, The products have passed CE, CB(IEC), SAA certificates and strictly comply with IEC standards. The company has advanced detection instruments and strong technical force with strong research and development capability, product constantly updated. The products export Europe, Asia, Southern Amercia, Middle East, Western Africa market.
If you are interested in any of our products or would like to discuss a custom order, please feel free to contact us. We are looking forward to forming successful business relationships with new clients around the world in the near future.
On the base of guarrantee the quality, we will try our best to design new model with ourselves patents for the coming years.
About Our Factory & Business Background
- Address
- No. 3999 Liujiang Road, Liushi Yueqing, Wenzhou, China.
- Terms of Payment
- LC, T/T, D/P, PayPal
- International Commercial Terms(Incoterms)
- FOB, EXW, CFR, CIF
- Average Lead Time
-
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays - Nearest Port
- NINGBO
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2016-01-08
- Main Markets
- South America, Eastern Europe, Southeast Asia, Africa, Mid East, Eastern Asia, Western Europe
FAQ
- What advantages do you have?
- We are the direct Manufacturer in Wenzhou China , we have professional,our teams have more than 20years experience in the field. developing, marketing & production team to offer you the most competitive price and best service.
- What's your main product?
- Circuit Breaker(MCB,RCCB/RCD, RCBO,ELCB, MCCB, ACB); Ac Contactor, Thermal Relay, Magnetic Starter; Isolator Switch, Changeover Switch, Push Button Switch, Voltage Protector...
- Could you print our own logo?
- Yes, Our company are available for Retail & Wholesale & OEM & ODM.
- How long is the quality guarantee?
- 18 month warranty, our products are 100% inspection.
- How long is the deliver time?
- It usually takes about 3 - 5 working days for sample order and 10 - 25 days for big order.
- What is your payment terms?
- Our Payment term is T/T, PayPal, L/C at sight.
- Any certification of your company or product?
- We have ISO 9001, CE, CB, SEMKO, SAA, TUV.
Send your message to this supplier
People who viewed this also viewed
-
US$75.00-80.00 / Piece
-
US$0.75-0.76 / Piece
-
US$3.82-3.95 / Piece
-
US$75.00-80.50 / Piece
-
US$42.52 / Piece
Product Groups
- RCBO Circuit Breaker
- Adjustable earth leakage circuit breaker
- Residual current circuit breaker
- Miniature circuit breaker
- Moulded case circuit breaker
- Motor Protection Circuit Breaker
- AC Contactor
- Magnetic Contactor
- Air Conditioning Contactor
- Thermal relay
- Solid State Relay
- Magnetic starter
Find Similar Products By Category
- Supplier Homepage
- Products
- Residual current circuit breaker
- Residual Current Circuit Breaker With Over Current Protectio
- 2p 4p Water Proof Leakage Current Circuit Breaker Multifunction
Related Categories
Hot Searches
- Electric Circuit Breaker Factories
- Vacuum Circuit Breaker Factories
- Miniature Circuit Breaker Factories
- Electrical Circuit Breaker Factories
- Circuit Breaker Switch
- Custom Circuit Breaker
- Circuit Breaker Protection Switch
- Protector Circuit Breaker
- Rcbo Breaker
- Circuit Breaker Bulkbuy